top of page

Forget what you already know about Treewire

Meet the New Generation
COVERED CONDUCTOR

1 - 132kV, 25-329 sqmm

Wildfire mitigation: 98,8%

Wildfire mitigation: 98,8% (CSIRO)

Total Capex (restringing): 120kUSD / circuit mile (159mm2 / 35kV / Western Europe)

Pilot line and training package: 40kUSD / circuit mile

Fully covered system

Low weight, sag and vibration

Saves time and reduces cost

Lowest environmental footprint

Amokabel’s Covered Conductor is the most cost-effective, reliable and safest solution for new powerline installations and retrofitting of existing overhead powerlines.

Our covered conductors prevent power outages and bushfires, while protecting wildlife, line workes as well as the environment.

Want to learn more? Click below!

WE PREVENT WILD FIRES

Climate Change increases the frequency and severity of high-risk weather events around the world, leading to an unprecedented bushfire risk. Research in Australia has found that bushfire seasons will start earlier and last longer, which leads to an increasing fire danger that poses an unacceptable risk to people, wildlife and properties.

Amokabel’s Covered Conductor provides a cost-effective method to reduce the risk of powerline-initiated bushfires by up to 99%.* CSIRO research has found that Covered Conductors are only marginally less effective than undergrounding at reducing fire risk and at a quarter of the cost, they provide the best benefit vs cost ratio on the market.

WE PREVENT POWER OUTAGES

Covered Conductor also provides a significant increase in network reliability on par with undergrounding and an order of magnitude better than bare conductor. In addition, Covered Conductor has an impressive expected service life of 45 years, equivalent to bare conductor.

With two thirds of power outages caused by vegetation contact, Covered Conductor can save utilities thousands of hours of supply interruptions, leading to greater customer satisfaction and less line crew intervention in difficult weather conditions.

In Scandinavia, the home of Amokabel, more than 100,000km of Covered Conductor have been installed solely for the reason of supply reliability.

WE SAVE LIVES

Lineworker injuries most often occur during high stress situations. Covered Conductor greatly reduces the number of occasions where line crews have perform troubleshooting during dangerous and stormy conditions. In addition, a downed Covered Conductor poses a much lower risk for the general public than a bare wire.

Wildlife contact with powerlines is one of the most common causes of outages. Covered Conductor effectively protects wildlife from electrocution in case of contact with the conductor. 

...or in other words, we create
RESILIENT AND SUSTAINABLE
POWER NETWORKS,
FAST AND COST EFFECTIVELY.

bottom of page